AS400IBM AS400 SoftwarePower 10 SystemsPower 9 SystemsIBM Flashsystems AS/400 Service & Support

Contact us for Pricing or Questions:      (888) 682-5335          *We Ship Worldwide
IBM AS400 iSeries IBM 1793 177GB SFF-2 SSD eMLC AIX Linux  .. Product #: 58B4-1793-00E6053-74E5296

IBM 1793 58B4 00E6053 74Y5296 177GB SFF-2 SSD eMLC AIX Linux

Brand: IBM AS400 iSeries
Model Number: 58B4-1793-00E6053-74E5296

IBM 1793 58B4 00E6053 74Y5296 177GB SFF-2 SSD eMLC AIX Linux IBM Power AIX Linux
The IBM 1793 177GB SFF-2 Solid State Drive (SSD) with eMLC for Power AIX and Linux systems has 58B4 CCIN and 00E6053 74Y5296 part numbers. The IBM 58B4 1793 177GB SFF-2 SSD is formatted to 528 byte sectors for AIX and Linux, and is the same solid state drive as the IBM 1794 for iSeries systems. The IBM 1793 SSD is supported in SFF-2 or gen2 SAS bays of IBM EXP24S 5887 I/O expansion drawers, and cannot be installed in IBM 5802 or 5803 I/O drawers due to physical difference in Gen1 and Gen2 carriers.
 
All IBM i iSeries and AS400 purchases include warranty, free technical support by phone or email and features and systems sold are guaranteed for IBM maintenance and support contracts.
 
The IBM 58B4 is supported on the following IBM Power System Models: 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2C, 8231-E2D, 8233-E8B, 8408-E8D, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9119-FHB, 9179-MHB, 9179-MHC, 9179-MHD
 
IBM 1793 58B4 00E6053 74Y5296 OS Requirements:
AIX Version 5.3 supported
AIX Version 6.1 supported
AIX Version 7.1 supported
SUSE Linux supported
Red Hat Linux supported
 
The SAS-bay-based SSDs (1775, 1787, 1793, 1794, 3586, 3587) support restrictions for Power7 systems:
  • SFF features 1775, 1787, 1793, and 1794, are supported in the Power 720 CEC.
  • 3.5-inch features 3586 and 3587 are not supported in the Power 720 CEC.
  • SSDs and HDDs are not allowed to mirror each other.
  • SSDs are not supported by features 5278, 5900, 5901, 5902, and 5912.
  • When an SSD is placed in feature EJ01, no feature 5886 or 5887 DASD drawer is allowed to connect to the system's external SAS port.
  • When an SSD is placed in a feature 5886 or 5887 DASD drawer, the drawer is not allowed to connect to the system's external SAS port.
  • A maximum of eight per feature 5886 drawer is allowed. No mixing of SSDs and HDDs is allowed in a feature 5886. A maximum of one feature 5886 EXP12S drawer containing SSDs attached to a single controller or pair of controllers is allowed. A feature 5886 containing SSD drives cannot be connected to other feature 5886's. A feature 5886 containing SSD drives cannot be attached to the CEC external SAS port on the Power 720.
  • In a Power 720 with a split backplane, SSDs and HDDs may be placed in either "split," but no mixing of SSDs and HDDs within a split is allowed. IBM i does not support split backplane.
  • In a Power 720 without a split backplane, SSDs and HDDs may be mixed in any combination. However, they cannot be in the same RAID array.